J Appl Clin Med Phys ; 25(1): e14221, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38029380

ABSTRACT

PURPOSE: Adaptive radiotherapy (ART) can improve the dose delivered to the patient in the presence of anatomic variations. However, the required time, effort, and clinical resources are intensive. This work analyzed a plan-of-the-day (POD) approach on clinical patients treated with online ART to explore implementations that balance dosimetric benefit and clinical resource cost. METHODS: Eight patients treated to the prostate and proximal seminal vesicles with 26 fractions of CBCT-guided, daily online ART were retrospectively analyzed. With a plan library composed of daily adaptive plans from the initial week of treatment and the original plan, the effect of a POD approach starting the following week was investigated by simulating use of these previously generated plans under 3- and 6-degree-of-freedom patient alignment. The plan selected for each treatment was that from the library that maximized the Dice similarity coefficient of the clinical target volume with that of the current treatment fraction. The resulting distribution of several target coverage and organ-at-risk dose metrics are described relative to those achieved with the daily online reoptimized adaptive technique. RESULTS: The values of target coverage and organ-at-risk dose metrics varied across patients and metrics. The POD schemas closely approximated the reference values from a fully reoptimized adaptive plan yet required less than 20% of the reoptimization effort. The POD schemas also had a much greater effect on target coverage metrics than 6-degree-of-freedom registration did. Organ-at-risk dose metrics also varied considerably across patients but did not exhibit a consistent dependence on the particular schema. CONCLUSIONS: POD schemas were able to achieve the vast majority of the dosimetric benefit of daily online ART with a small fraction of the online reoptimization effort. Strategies like this might allow for more practical and strategic implementation of ART so as to benefit a greater number of patients.


Subject(s)
Radiotherapy, Image-Guided , Radiotherapy, Intensity-Modulated , Spiral Cone-Beam Computed Tomography , Male , Humans , Prostate , Radiotherapy Planning, Computer-Assisted/methods , Retrospective Studies , Radiometry , Radiotherapy Dosage , Radiotherapy, Image-Guided/methods , Radiotherapy, Intensity-Modulated/methods
2.
Phys Med Biol ; 68(19)2023 09 27.
Article in English | MEDLINE | ID: mdl-37673075

ABSTRACT

Objective.Treating multiple brain metastases in a single plan is a popular radiosurgery technique. However, targets positioned off-isocenter are subject to rotational uncertainties. This work introduces two new planning target volumes (PTVs) that address this increased uncertainty. The volume of normal tissue included in these PTVs when paired with optimized isocenters are evaluated and compared with conventional methods.Approach.Sets of 1000 random multi-target radiosurgery patients were simulated, each patient with a random number of spherical targets (2-10). Each target had a random volume (0.1-15 cc) and was randomly positioned between 5 and 50 mm or 100 mm from isocenter. Two new PTVs ('LensPTV' and 'SwipePTV') and conventional isotropic PTVs were created using isocenters derived from the center-of-centroids, the center-of-mass, or optimized per PTV type. The total volume of normal tissue in the PTVs for each patient was calculated and compared using 1 mm translations and 0.5°, 1.0°, and 2.0° rotations.Main results.Using the new PTVs and/or using optimized isocenters decreased the total volume of normal tissue in the PTVs per patient. The SwipePTV, in particular, provided the greatest decrease. Compared to the SwipePTV, the LensPTV and the conventional isotropic PTV included an extra 0.68 and 0.73 cc of normal tissue per patient (median), respectively, when using 50 mm max distance to isocenter and 1° max rotation angle. Under these conditions, 25% of patients had extra volume of normal tissue ≥ 0.96 and 1.04 cc. When using 100 mm max distance to isocenter and 2° max rotation angle, 25% of patients had extra volume of normal tissue ≥ 4.35 and 5.75 cc.Significance.PTVs like those presented here, especially when paired with optimized isocenters, can decrease the total volume of included normal tissue and reduce the risk of toxicity without compromising target coverage.


Subject(s)
Brain Neoplasms , Radiosurgery , Radiotherapy, Intensity-Modulated , Humans , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy Dosage , Radiosurgery/methods , Uncertainty , Brain Neoplasms/diagnostic imaging , Brain Neoplasms/radiotherapy , Brain Neoplasms/pathology , Radiotherapy, Intensity-Modulated/methods
3.
J Appl Clin Med Phys ; 24(10): e14060, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37276079

ABSTRACT

BACKGROUND: Online adaptive radiotherapy (ART) can address dosimetric consequences of variations in anatomy by creating a new plan during treatment. However, ART is time- and labor-intensive and should be implemented in a resource-conscious way. Adaptive triggers composed of parameter-value pairs may direct the judicious use of online ART. PURPOSE: This work analyzed our clinical experience using CBCT-based daily online ART to demonstrate how a conceptual framework based on adaptive triggers affects the dosimetric and procedural impact of ART. METHODS: Sixteen patients across several pelvic sites were treated with CBCT-based daily online ART. Differences in standardized dose metrics were compared between the original plan, the original plan recalculated on the daily anatomy, and an adaptive plan. For each metric, trigger values were analyzed in terms of the proportion of treatments adapted and the distribution of metric values. RESULTS: Target coverage metrics were compromised due to anatomic variation with the average change per treatment ranging from -0.90 to -0.05 Gy, -0.47 to -0.02 Gy, -0.31 to -0.01 Gy, and -12.45% to -2.65% for PTV D99%, PTV D95%, CTV D99%, and CTV V100%, respectively. These were improved using the adaptive plan (-0.03 to 0.01 Gy, -0.02 to 0.00 Gy, -0.03 to 0.00 Gy, and -4.70% to 0.00%, respectively). Increasingly strict triggers resulted in a non-linear increase in the proportion of treatments adapted and improved the distribution of metric values with diminishing returns. Some organ-at-risk (OAR) metrics were compromised by anatomic variation and improved using the adaptive plan, but changes in most OAR metrics were randomly distributed. CONCLUSIONS: Daily online ART improved target coverage across multiple pelvic treatment sites and techniques. These effects were larger than those for OAR metrics, suggesting that maintaining target coverage was our primary benefit of CBCT-based daily online ART. Analyses like these can determine online ART triggers from a cost-benefit perspective.


Subject(s)
Radiotherapy, Image-Guided , Radiotherapy, Intensity-Modulated , Humans , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Image-Guided/methods , Organs at Risk , Radiotherapy Dosage , Pelvis , Radiotherapy, Intensity-Modulated/methods
4.
Adv Radiat Oncol ; 8(3): 101034, 2023.
Article in English | MEDLINE | ID: mdl-37273924

ABSTRACT

Purpose: Changes in patient anatomy and tumor geometry pose a challenge to ensuring consistent target coverage and organ-at-risk sparing; online adaptive radiation therapy (ART) accounts for these interfractional changes by facilitating replanning before each treatment. This project explored the opportunity cost of computed tomography (CT)-based online ART by evaluating time and human resource requirements. Time-driven activity-based costing (TDABC) was employed to determine the cost of this time to assess if the dosimetric benefit is worthwhile. Methods and Materials: CT-based online ART was recently employed at our institution and has been used to treat pelvic disease sites (prostate, prostate bed, prostate with nodal coverage, bladder, rectum); data points from all adaptively treated patients (415 fractions) were used. Time taken for each adaptive fraction before treatment, which at our facility is best represented by the duration between 2 cone beam CT scans, was used as a broadly applicable and transferable metric, representing the additional time required for ART on top of standard image guided radiation therapy. Dosimetric effect was also considered by taking the difference of planning target volume V100% for the scheduled and adapted plans. Using recently validated TDABC at this facility, the per fraction cost of ART was determined, reflecting the added cost of ART on top of image guided radiation therapy. Results: A median time of 15.97 (interquartile range, 13.23-18.83) additional minutes was required for each adaptive fraction. TDABC demonstrated an average minimum cost per adapted fraction of $103.58. Dosimetric differences between V100% of the scheduled versus adapted plan showed a mean dosimetric difference of 15.8%. Conclusions: Although online ART decreases the uncertainty of anatomic shifts, each adaptive fraction requires more staff time, delaying completion of other tasks and increasing resource utilization. Although toxicity benefits require further studies, the implementation of progressively complex radiation therapy technologies, like ART, requires consideration of the time and human resource requirements and subsequent opportunity cost.

5.
Med Phys ; 48(12): 7623-7631, 2021 Dec.
Article in English | MEDLINE | ID: mdl-34726271

ABSTRACT

PURPOSE: This work evaluated a new radiotherapy target-generating framework (the αTarget algorithm) for creating internal target volumes for lung SBRT. METHODS: Nineteen patients previously treated with definitive intent SBRT to the lung were identified from a clinical database. For each patient's 4DCT simulation scan, deformable image registration was used between phases of the scan in order to generate voxelized models of motion for 35 individual gross tumor volumes. These motion models were then used with a new implementation of a previously described target-generating algorithm to create new internal target volumes (αITVs). The resulting αITVs were analyzed with respect to their volume and the coverage they provided each tumor voxel per that voxel's motion model. The clinically used ITVs were similarly analyzed, and were then compared to the αITVs using paired Student's t-tests. In addition, isotropic margins were added to the αITVs in order to determine the largest margin magnitude that could be added without exceeding the volume of the clinical ITVs. RESULTS: The αITVs increased the target coverage provided to each tumor's 5th-percentile-most-covered-voxel an average of 50.3% compared to the clinical ITVs (p < 0.0001). At the same time, the αITVs had volumes that were, on average, 31.4% smaller (p < 0.0001). The differences in volume were large enough that, on average, an extra 2 mm isotropic margin could be added to the αITV before it had a volume greater than the clinical ITV. CONCLUSIONS: The αTarget algorithm can generate more effective lung SBRT internal target volumes that provide greater coverage with smaller volumes. In combination with numerous other advantages of the framework, this effectiveness makes the αTarget algorithm a powerful new method for advanced IGRT or adaptive radiotherapy techniques.


Subject(s)
Lung Neoplasms , Radiosurgery , Algorithms , Humans , Lung , Lung Neoplasms/diagnostic imaging , Lung Neoplasms/radiotherapy , Lung Neoplasms/surgery , Uncertainty
6.
J Appl Clin Med Phys ; 22(10): 210-221, 2021 Oct.
Article in English | MEDLINE | ID: mdl-34529332

ABSTRACT

PURPOSE: This provides a benchmark of dosimetric benefit and clinical cost of cone-beam CT-based online adaptive radiotherapy (ART) technology for cervical and rectal cancer patients. METHODS: An emulator of a CBCT-based online ART system was used to simulate more than 300 treatments for 13 cervical and 15 rectal cancer patients. CBCT images were used to generate adaptive replans. To measure clinical resource cost, the six phases of the workflow were timed. To evaluate the dosimetric benefit, changes in dosimetric values were assessed. These included minimum dose (Dmin) and volume receiving 95% of prescription (V95%) for the planning target volume (PTV) and the clinical target volume (CTV), and maximum 2 cc's (D2cc) of the bladder, bowel, rectum, and sigmoid colon. RESULTS: The average duration of the workflow was 24.4 and 9.2 min for cervical and rectal cancer patients, respectively. A large proportion of time was dedicated to editing target contours (13.1 and 2.7 min, respectively). For cervical cancer patients, the replan changed the Dmin to the PTVs and CTVs for each fraction 0.25 and 0.25 Gy, respectively. The replan changed the V95% by 9.2 and 7.9%. The D2cc to the bladder, bowel, rectum, and sigmoid colon for each fraction changed -0.02, -0.08, -0.07, and -0.04 Gy, respectively. For rectal cancer patients, the replan changed the Dmin to the PTVs and CTVs for each fraction of 0.20 and 0.24 Gy, respectively. The replan changed the V95% by 4.1 and 1.5%. The D2cc to the bladder and bowel for each fraction changed 0.02 and -0.02 Gy, respectively. CONCLUSIONS: Dosimetric benefits can be achieved with CBCT-based online ART that is amenable to conventional appointment slots. The clinical significance of these benefits remains to be determined. Managing contours was the primary factor affecting the total duration and is imperative for safe and effective adaptive radiotherapy.


Subject(s)
Radiotherapy, Image-Guided , Radiotherapy, Intensity-Modulated , Spiral Cone-Beam Computed Tomography , Uterine Cervical Neoplasms , Female , Humans , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Rectum/diagnostic imaging , Uterine Cervical Neoplasms/diagnostic imaging , Uterine Cervical Neoplasms/radiotherapy
7.
Int J Radiat Oncol Biol Phys ; 109(4): 1054-1075, 2021 03 15.
Article in English | MEDLINE | ID: mdl-33470210

ABSTRACT

The integration of adaptive radiation therapy (ART), or modifying the treatment plan during the treatment course, is becoming more widely available in clinical practice. ART offers strong potential for minimizing treatment-related toxicity while escalating or de-escalating target doses based on the dose to organs at risk. Yet, ART workflows add complexity into the radiation therapy planning and delivery process that may introduce additional uncertainties. This work sought to review presently available ART workflows and technological considerations such as image quality, deformable image registration, and dose accumulation. Quality assurance considerations for ART components and minimum recommendations are described. Personnel and workflow efficiency recommendations are provided, as is a summary of currently available clinical evidence supporting the implementation of ART. Finally, to guide future clinical trial protocols, an example ART physician directive and a physics template following standard NRG Oncology protocol is provided.


Subject(s)
Radiotherapy Planning, Computer-Assisted/methods , Brachytherapy , Clinical Trials as Topic , Humans , Organs at Risk , Quality Assurance, Health Care , Radiotherapy Dosage , Radiotherapy, Image-Guided , Tomography, X-Ray Computed , Workflow
8.
Radiother Oncol ; 152: 169-176, 2020 11.
Article in English | MEDLINE | ID: mdl-32291110

ABSTRACT

BACKGROUND AND PURPOSE: Lymphopenia is associated with poor outcomes in esophageal cancer (EC) patients undergoing chemoradiotherapy (CRT). We hypothesized that radiation dose to marrow (central) vs. circulating (peripheral) leukocytes (WBCs) may have unique effects on WBC counts and clinical outcomes in EC. MATERIALS AND METHODS: Weekly and 90-day post-CRT blood cell counts were evaluated for 46 patients with stage II-III EC treated with CRT. Thoracic vertebral volume spared (TVS) radiation was extracted from dose volume histograms (DVH). Mean cardiopulmonary dose (mCPD) was calculated as mean dose to the volumetric sum of heart, lungs, and great vessels as a surrogate for circulating blood pool. Linear and logistic regression identified associations between dosimetric variables and hematologic toxicities (HT). Repeated measures ANOVA tested associations between cell count trends and clinical predictors. RESULTS: WBCs and platelets reached nadir at week 6 of CRT. On multivariate analysis, mCPD was associated with lower WBC and neutrophil nadirs (p < 0.05). TVS5-40 Gy were associated with higher lymphocyte nadirs (all p < 0.05). Repeated measures ANOVA revealed an interaction effect of sex on absolute lymphocyte trend as well as age (<67 vs. >67) and diabetes on normalized lymphocyte trend (all p < 0.015). CONCLUSIONS: mCPD and volume of thoracic marrow spared radiation differentially predict lineage-specific leukopenias during CRT for EC. mCPD is significantly associated with lower total WBC and neutrophil nadirs. In contrast, greater thoracic marrow spared radiation is associated with mitigation of lymphopenia during CRT. Clinical factors such as sex, age, and diabetes may be associated with a more rapid decline in hematologic counts during treatment.


Subject(s)
Esophageal Neoplasms , Leukopenia , Antineoplastic Combined Chemotherapy Protocols , Bone Marrow , Chemoradiotherapy/adverse effects , Humans , Kinetics , Leukopenia/etiology , Radiotherapy Dosage
9.
Phys Imaging Radiat Oncol ; 14: 67-73, 2020 Apr.
Article in English | MEDLINE | ID: mdl-33458317

ABSTRACT

BACKGROUND AND PURPOSE: Conical scintillation detectors are frequently used to measure geometric characteristics of radiotherapy modalities. However, their application to verify intensity-modulated radiotherapy plan delivery has not been investigated and requires a more detailed understanding of device response. This work evaluated the novel application of a conical scintillation detector to plan-specific quality assurance (QA) for intensity-modulated photon plans by evaluating device dependence on beam delivery and device acquisition parameters. MATERIALS AND METHODS: Measurements were made with a conical scintillation detector using beam delivery parameters of five photon beams (6-15 MV, including flattening filter free), three field sizes (1 × 1-5 × 5 cm2), and several dose rates (100-2000 MU/min) combined with device acquisition parameters of two frame rates (10 and 20 fps) and three gains (18-22 dB). A standardization equation to correct for gain and frame rate was investigated, and the remaining dose rate dependence was characterized. Device precision was evaluated using replicate measurements, and spatial uniformity was determined by irradiating different parts of the device. RESULTS: For each parameter combination, measurement reproducibility was 1.3%, and spatial uniformity was 1-2%. Scintillation intensity varied with gain, frame rate, and dose rate. Standardizing measurements for gain and frame rate was effective, but a dependence on dose rate caused errors at non-reference conditions (root mean squared error, RMSE: 0-152%). An additional dose rate correction specific to each combination of gain and frame rate improved accuracy (RMSE 0-17%). CONCLUSIONS: To consider the detector for plan-specific QA of intensity-modulated radiotherapy plans, correction factors are imperative to mitigate effects of delivery and acquisition parameters.

10.
Phys Med Biol ; 64(13): 135009, 2019 07 04.
Article in English | MEDLINE | ID: mdl-31189137

ABSTRACT

Stereotactic body radiotherapy (SBRT) of the lung has become a standard of care for early-stage inoperable non-small cell lung cancer (NSCLC). A common strategy to manage respiratory motion is gating, which inevitably results in an increase in treatment time, especially in irregularly-breathing patients. Flattening-filter free (FFF) beams allow for delivery of the treatment at a higher dose rate, therefore counteracting the lengthened treatment time due to frequent interruption of the beam during gated radiotherapy. In this study, we perform our in vitro evaluation of the dosimetric and radiobiological effect of gated lung SBRT with simultaneous integrated boost (SIB) using both flattened and FFF beams. A moving thorax-shaped phantom with inserts and applicators was used for simulation, planning, gated treatment delivery measurements and in vitro tests. The effects of gating window, dose rate, and breathing pattern were evaluated. Planned doses represented a typical conventional fractionation, 200 cGy per fraction with SIB to 240 cGy, flattened beam only, and SBRT, 800 cGy with SIB to 900 cGy, flattened and FFF beams. Ideal, as well as regular and irregular patient-specific breathing patterns with and without gating were used. A survival assay for lung adenocarcinoma A549 cell line was performed. Delivered dose was within 6% for locations planned to receive 200 and 800 cGy and within 4% for SIB locations. Time between first beam-on and last beam-off varied from approximately 1.5 min for conventional fractionation, 200/240 cGy, to 10.5 min for gated SBRT, 800/900 cGy doses, flattened beam and irregular breathing motion pattern. With FFF beams dose delivery time was shorter by a factor of 2-3, depending on the gating window and breathing pattern. We have found that, for the most part, survival depended on dose and not on dose rate, gating window, or breathing regularity.


Subject(s)
Lung Neoplasms/pathology , Radiation Dose Hypofractionation , Radiobiology , Radiosurgery/methods , Respiration , A549 Cells , Humans , Lung Neoplasms/physiopathology , Lung Neoplasms/radiotherapy , Phantoms, Imaging , Radiometry , Radiotherapy Planning, Computer-Assisted
11.
Pract Radiat Oncol ; 9(4): 200-207, 2019.
Article in English | MEDLINE | ID: mdl-30562614

ABSTRACT

PURPOSE: With external beam radiation therapy, uncertainties in treatment planning and delivery can result in an undesirable dose distribution delivered to the patient that can compromise the benefit of treatment. Techniques including geometric margins and probabilistic optimization have been used effectively to mitigate the effects of uncertainties. However, their broad application is inconsistent and can compromise the conclusions derived from cross-technique and cross-modality comparisons. METHODS AND MATERIALS: Conventional methods to deal with treatment planning and delivery uncertainties are described, and robustness analysis is presented as a framework that is applicable across treatment techniques and modalities. RESULTS: This report identifies elements that are imperative to include when conducting a robustness analysis and describing uncertainties and their dosimetric effects. CONCLUSION: The robustness analysis approach described here is presented to promote reliable plan evaluation and dose reporting, particularly during clinical trials conducted across institutions and treatment modalities.


Subject(s)
Radiotherapy Dosage/standards , Radiotherapy Planning, Computer-Assisted/methods , Humans , Uncertainty
12.
Comput Methods Programs Biomed ; 166: 1-8, 2018 Nov.
Article in English | MEDLINE | ID: mdl-30415709

ABSTRACT

BACKGROUND AND SIGNIFICANCE: This work provides proof-of-principle for two versions of a heuristic approach that automatically creates amorphous radiation therapy planning target volume (PTV) margins considering local effects of tumor shape and motion to ensure adequate voxel coverage with while striving to minimize PTV size. The resulting target thereby promotes disease control while minimizing the risk of normal tissue toxicity. METHODS: This work describes the mixed-PDF algorithm and the independent-PDF algorithm which generate amorphous margins around a radiation therapy target by incorporating user-defined models of target motion. Both algorithms were applied to example targets - one circular and one "cashew-shaped." Target motion was modeled by four probability density functions applied to the target quadrants. The spatially variant motion model illustrates the application of the algorithms even with tissue deformation. Performance of the margins was evaluated in silico with respect to voxelized target coverage and PTV size, and was compared to conventional techniques: a threshold-based probabilistic technique and an (an)isotropic expansion technique. To demonstrate the algorithm's clinical utility, a lung cancer patient was analyzed retrospectively. For this case, 4D CT measurements were combined with setup uncertainty to compare the PTV from the mixed-PDF algorithm with a PTV equivalent to the one used clinically. RESULTS: For both targets, the mixed-PDF algorithm performed best, followed by the independent-PDF algorithm, the threshold algorithm, and lastly, the (an)isotropic algorithm. Superior coverage was always achieved by the amorphous margin algorithms for a given PTV size. Alternatively, the margin required for a particular level of coverage was always smaller (8-15%) when created with the amorphous algorithms. For the lung cancer patient, the mixed-PDF algorithm resulted in a PTV that was 13% smaller than the clinical PTV while still achieving ≥99.9% coverage. CONCLUSIONS: The amorphous margin algorithms are better suited for the local effects of target shape and positional uncertainties than conventional margins. As a result, they provide superior target coverage with smaller PTVs, ensuring dose delivered to the target while decreasing the risk of normal tissue toxicity.


Subject(s)
Lung Neoplasms/radiotherapy , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods , Algorithms , Four-Dimensional Computed Tomography , Humans , Lung Neoplasms/pathology , Motion , Probability , Software
13.
Int J Radiat Oncol Biol Phys ; 101(5): 1027, 2018 08 01.
Article in English | MEDLINE | ID: mdl-30012522
14.
J Appl Clin Med Phys ; 19(3): 355-359, 2018 May.
Article in English | MEDLINE | ID: mdl-29500846

ABSTRACT

PURPOSE: The purpose of this study was to develop and test a set of illustrated instructions for effective training for mechanical quality assurance (QA) of medical linear accelerators (linac). METHODS: Illustrated instructions were created for mechanical QA and underwent several steps of review, testing, and refinement. Eleven testers with no recent QA experience were then recruited from our radiotherapy department (one student, two computational scientists, and eight dosimetrists). This group was selected because they have experience of radiation therapy but no preconceived ideas about how to do QA. The following parameters were progressively decalibrated on a Varian C-series linac: Group A = gantry angle, ceiling laser position, X1 jaw position, couch longitudinal position, physical graticule position (five testers); Group B = Group A + wall laser position, couch lateral and vertical position, collimator angle (three testers); Group C = Group B + couch angle, wall laser angle, and optical distance indicator (three testers). Testers were taught how to use the linac and then used the instructions to try to identify these errors. An experienced physicist observed each session, giving support on machine operation as necessary. RESULTS: Testers were able to follow the instructions. They determined gantry, collimator, and couch angle errors within 0.4°, 0.3°, and 0.9° of the actual changed values, respectively. Laser positions were determined within 1 mm and jaw positions within 2 mm. Couch position errors were determined within 2 mm and 3 mm for lateral/longitudinal and vertical errors, respectively. Accessory-positioning errors were determined within 1 mm. Optical distance indicator errors were determined within 2 mm when comparing with distance sticks and 6 mm when using blocks, indicating that distance sticks should be the preferred approach for inexperienced staff. CONCLUSIONS: Inexperienced users were able to follow these instructions and catch errors within the criteria suggested by AAPM TG-142 for linacs used for intensity-modulated radiation therapy. These instructions are, therefore, suitable for QA training.


Subject(s)
Particle Accelerators/standards , Quality Assurance, Health Care/standards , Quality Control , Radiotherapy/instrumentation , Calibration , Humans , Mechanical Phenomena , Software
15.
Med Phys ; 44(10): 5467-5474, 2017 Oct.
Article in English | MEDLINE | ID: mdl-28766726

ABSTRACT

PURPOSE: To construct a 3D-printed phantom insert designed to mimic the variable PET tracer uptake seen in lung tumor volumes and a matching dosimetric insert to be used in simultaneous integrated boost (SIB) phantom studies, and to evaluate the design through end-to-end tests. METHODS: A set of phantom inserts was designed and manufactured for a realistic representation of gated radiotherapy steps from 4D PET/CT scanning to dose delivery. A cylindrical phantom (φ80 × 120 mm) holds inserts for PET/CT scanning. The novel 3D printed insert dedicated to 4D PET/CT mimics high PET tracer uptake in the core and low uptake in the periphery. This insert is a variable density porous cylinder (φ44.5 × 70.0 mm), ABS-P430 thermoplastic, 3D printed by fused deposition modeling an inner (φ11 × 42 mm) cylindrical void. The square pores (1.8 × 1.8 mm2 each) fill 50% of outer volume, resulting in a 2:1 PET tracer concentration ratio in the void volume with respect to porous volume. A matching cylindrical phantom insert is dedicated to validate gated radiotherapy. It contains eight peripheral holes and one central hole, matching the location of the porous part and the void part of the 3D printed insert, respectively. These holes accommodate adaptors for Farmer-type ion chamber and cells vials. End-to-end tests were designed for imaging, planning, and dose measurements. RESULTS: End-to-end test were performed from 4D PET/CT scanning to transferring data to the planning system, target volume delineation, and dose measurements. 4D PET/CT scans were acquired of the phantom at different respiratory motion patterns and gating windows. A measured 2:1 18F-FDG concentration ratio between inner void and outer porous volume matched the 3D printed design. Measured dose in the dosimetric insert agreed well with planned dose on the imaging insert, within 3% for the static phantom and within 5% for most breathing patterns. CONCLUSIONS: The novel 3D printed phantom insert mimics variable PET tracer uptake typical of tumors. Obtained 4D PET/CT scans are suitable for segmentation and treatment planning and delivery in SIB gated treatments. Our experiments demonstrate the feasibility of this set of phantom inserts serving as end-to-end quality-assurance phantoms of SIB radiotherapy.


Subject(s)
Four-Dimensional Computed Tomography/instrumentation , Phantoms, Imaging , Positron Emission Tomography Computed Tomography/instrumentation , Printing, Three-Dimensional , Surgery, Computer-Assisted/instrumentation , Fluorodeoxyglucose F18 , Image Processing, Computer-Assisted , Radiometry , Time Factors
16.
J Appl Clin Med Phys ; 18(5): 351-357, 2017 Sep.
Article in English | MEDLINE | ID: mdl-28727284

ABSTRACT

PURPOSE: To present the k-means clustering algorithm as a tool to address treatment planning considerations characteristic of stereotactic radiosurgery using a single isocenter for multiple targets. METHODS: For 30 patients treated with stereotactic radiosurgery for multiple brain metastases, the geometric centroids and radii of each met were determined from the treatment planning system. In-house software used this as well as weighted and unweighted versions of the k-means clustering algorithm to group the targets to be treated with a single isocenter, and to position each isocenter. The algorithm results were evaluated using within-cluster sum of squares as well as a minimum target coverage metric that considered the effect of target size. Both versions of the algorithm were applied to an example patient to demonstrate the prospective determination of the appropriate number and location of isocenters. RESULTS: Both weighted and unweighted versions of the k-means algorithm were applied successfully to determine the number and position of isocenters. Comparing the two, both the within-cluster sum of squares metric and the minimum target coverage metric resulting from the unweighted version were less than those from the weighted version. The average magnitudes of the differences were small (-0.2 cm2 and 0.1% for the within cluster sum of squares and minimum target coverage, respectively) but statistically significant (Wilcoxon signed-rank test, P < 0.01). CONCLUSIONS: The differences between the versions of the k-means clustering algorithm represented an advantage of the unweighted version for the within-cluster sum of squares metric, and an advantage of the weighted version for the minimum target coverage metric. While additional treatment planning considerations have a large influence on the final treatment plan quality, both versions of the k-means algorithm provide automatic, consistent, quantitative, and objective solutions to the tasks associated with SRS treatment planning using a single isocenter for multiple targets.


Subject(s)
Algorithms , Brain Neoplasms/radiotherapy , Brain Neoplasms/secondary , Radiosurgery/methods , Humans , Prospective Studies , Radiotherapy Planning, Computer-Assisted , Software
17.
Med Phys ; 43(12): 6347, 2016 Dec.
Article in English | MEDLINE | ID: mdl-27908165

ABSTRACT

PURPOSE: To examine the abilities of a traditional failure mode and effects analysis (FMEA) and modified healthcare FMEA (m-HFMEA) scoring methods by comparing the degree of congruence in identifying high risk failures. METHODS: The authors applied two prospective methods of the quality management to surface image guided, linac-based radiosurgery (SIG-RS). For the traditional FMEA, decisions on how to improve an operation were based on the risk priority number (RPN). The RPN is a product of three indices: occurrence, severity, and detectability. The m-HFMEA approach utilized two indices, severity and frequency. A risk inventory matrix was divided into four categories: very low, low, high, and very high. For high risk events, an additional evaluation was performed. Based upon the criticality of the process, it was decided if additional safety measures were needed and what they comprise. RESULTS: The two methods were independently compared to determine if the results and rated risks matched. The authors' results showed an agreement of 85% between FMEA and m-HFMEA approaches for top 20 risks of SIG-RS-specific failure modes. The main differences between the two approaches were the distribution of the values and the observation that failure modes (52, 54, 154) with high m-HFMEA scores do not necessarily have high FMEA-RPN scores. In the m-HFMEA analysis, when the risk score is determined, the basis of the established HFMEA Decision Tree™ or the failure mode should be more thoroughly investigated. CONCLUSIONS: m-HFMEA is inductive because it requires the identification of the consequences from causes, and semi-quantitative since it allows the prioritization of high risks and mitigation measures. It is therefore a useful tool for the prospective risk analysis method to radiotherapy.


Subject(s)
Healthcare Failure Mode and Effect Analysis/methods , Humans , Prospective Studies , Radiotherapy/adverse effects , Radiotherapy Dosage
18.
Med Phys ; 43(7): 4342, 2016 Jul.
Article in English | MEDLINE | ID: mdl-27370149

ABSTRACT

PURPOSE: In surface image guided radiosurgery, action limits are created to determine at what point intrafractional motion exhibited by the patient is large enough to warrant intervention. Action limit values remain constant across patients despite the fact that patient motion affects the target coverage of brain metastases differently depending on the planning technique and other treatment plan-specific factors. The purpose of this work was twofold. The first purpose was to characterize the sensitivity of single-met per iso and multimet per iso treatment plans to uncorrected patient motion. The second purpose was to describe a method to prospectively determine treatment plan-specific action limits considering this sensitivity. METHODS: In their surface image guided radiosurgery technique, patient positioning is achieved with a thermoplastic mask that does not cover the patient's face. The patient's exposed face is imaged by a stereoscopic photogrammetry system. It is then compared to a reference surface and monitored throughout treatment. Seventy-two brain metastases (representing 29 patients) were used for this study. Twenty-five mets were treated individually ("single-met per iso plans"), and 47 were treated in a plan simultaneously with at least one other met ("multimet per iso plans"). For each met, the proportion of the gross tumor volume that remained within the 100% prescription isodose line was estimated under the influence of combinations of translations and rotations (0.0-3.0 mm and 0.0°-3.0°, respectively). The target volume and the prescription dose-volume were considered concentric spheres that each encompassed a volume determined from the treatment plan. Plan-specific contour plots and DVHs were created to illustrate the sensitivity of a specific lesion to uncorrected patient motion. RESULTS: Both single-met per iso and multimet per iso plans exhibited compromised target coverage under translations and rotations, though multimet per iso plans were considerably more sensitive to these transformations (2.3% and 39.8%, respectively). Plan-specific contour plots and DVHs were used to illustrate how size, distance from isocenter, and planning technique affect a particular met's sensitivity to motion. CONCLUSIONS: Stereotactic radiosurgery treatment plans that treat multiple brain metastases using a common isocenter are particularly susceptible to compromised target coverage as a result of uncorrected patient motion. The use of such a planning technique along with other treatment plan-specific factors should influence patient motion management. A graphical representation of the effect of translations and rotations on any particular plan can be generated to inform clinicians of the appropriate action limit when monitoring intrafractional motion.


Subject(s)
Brain Neoplasms/diagnostic imaging , Brain Neoplasms/surgery , Radiosurgery/methods , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Image-Guided/methods , Brain Neoplasms/secondary , Humans , Motion , Radiotherapy Dosage , Time Factors
19.
J Appl Clin Med Phys ; 17(1): 246-258, 2016 01 08.
Article in English | MEDLINE | ID: mdl-26894362

ABSTRACT

The purpose of this study was to develop an approach to generate artificial computed tomography (CT) images with known deformation by learning the anatomy changes in a patient population for voxel-level validation of deformable image registration. Using a dataset of CT images representing anatomy changes during the course of radiation therapy, we selected a reference image and registered the remaining images to it, either directly or indirectly, using deformable registration. The resulting deformation vector fields (DVFs) represented the anatomy variations in that patient population. The mean deformation, computed from the DVFs, and the most prominent variations, which were captured using principal component analysis (PCA), composed an active shape model that could generate random known deformations with realistic anatomy changes based on those learned from the patient population. This approach was applied to a set of 12 head and neck patients who received intensity-modulated radiation therapy for validation. Artificial planning CT and daily CT images were generated to simulate a patient with known anatomy changes over the course of treatment and used to validate the deformable image registration between them. These artificial CT images potentially simulated the actual patients' anatomies and also showed realistic anatomy changes between different daily CT images. They were used to successfully validate deformable image registration applied to intrapatient deformation.


Subject(s)
Computer Simulation , Head and Neck Neoplasms/pathology , Image Processing, Computer-Assisted/methods , Phantoms, Imaging , Tomography, X-Ray Computed/methods , Algorithms , Head and Neck Neoplasms/radiotherapy , Humans , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Radiotherapy, Intensity-Modulated , Retrospective Studies
20.
Med Phys ; 41(8): 081708, 2014 Aug.
Article in English | MEDLINE | ID: mdl-25086518

ABSTRACT

PURPOSE: To create models that forecast longitudinal trends in changing tumor morphology and to evaluate and compare their predictive potential throughout the course of radiation therapy. METHODS: Two morphology feature vectors were used to describe 35 gross tumor volumes (GTVs) throughout the course of intensity-modulated radiation therapy for oropharyngeal tumors. The feature vectors comprised the coordinates of the GTV centroids and a description of GTV shape using either interlandmark distances or a spherical harmonic decomposition of these distances. The change in the morphology feature vector observed at 33 time points throughout the course of treatment was described using static, linear, and mean models. Models were adjusted at 0, 1, 2, 3, or 5 different time points (adjustment points) to improve prediction accuracy. The potential of these models to forecast GTV morphology was evaluated using leave-one-out cross-validation, and the accuracy of the models was compared using Wilcoxon signed-rank tests. RESULTS: Adding a single adjustment point to the static model without any adjustment points decreased the median error in forecasting the position of GTV surface landmarks by the largest amount (1.2 mm). Additional adjustment points further decreased the forecast error by about 0.4 mm each. Selection of the linear model decreased the forecast error for both the distance-based and spherical harmonic morphology descriptors (0.2 mm), while the mean model decreased the forecast error for the distance-based descriptor only (0.2 mm). The magnitude and statistical significance of these improvements decreased with each additional adjustment point, and the effect from model selection was not as large as that from adding the initial points. CONCLUSIONS: The authors present models that anticipate longitudinal changes in tumor morphology using various models and model adjustment schemes. The accuracy of these models depended on their form, and the utility of these models includes the characterization of patient-specific response with implications for treatment management and research study design.


Subject(s)
Models, Biological , Oropharyngeal Neoplasms/pathology , Oropharyngeal Neoplasms/radiotherapy , Radiotherapy, Intensity-Modulated , Adult , Aged , Disease Progression , Forecasting , Humans , Linear Models , Middle Aged , Oropharyngeal Neoplasms/diagnosis , Prognosis , Radiotherapy, Intensity-Modulated/methods , Randomized Controlled Trials as Topic , Retrospective Studies , Time , Tomography, X-Ray Computed , Tumor Burden/radiation effects